Contact us to request a quote info@tezgen.com
Contact us to request a quote info@tezgen.com
  +90 212 993 14 37
  • Apera%20DO8500%20Portable%20Optical%20Dissolved%20Oxygen%20Meter%20Kit%20Data%20Logger%20and%20Automatic%20Salinity
  • Apera%20DO8500%20Portable%20Optical%20Dissolved%20Oxygen%20Meter%20Kit%20Data%20Logger%20and%20Automatic%20Salinity
  • Apera%20DO8500%20Portable%20Optical%20Dissolved%20Oxygen%20Meter%20Kit%20Data%20Logger%20and%20Automatic%20Salinity
Apera DO8500 Portable Optical Dissolved Oxygen Meter Kit Data Logger and Automatic Salinity
Product code : Apera DO8500 Taşınabilir Optik Çözünmüş Oksijen Ölçer
Marka :  Apera Instruments

Apera DO8500 Portable Optical Dissolved Oxygen Meter Kit Data Logger and Automatic Salinity

State-of-the-art Optical DO sensor measures dissolved oxygen RELIABLY and EFFORTLESS

Minimal maintenance required. Quick and easy calibration

Automatic compensation for salinity, temperature and air pressure

GLP/GMP data management, 500 data sets storage, USB data output

Meter comes with a complete test kit including a 10 ft optical probe and salinity probe, a calibration cap and a rugged carrying case

 

Probe head diameter for DO803 Luminescent Optical DO Probe: approximately 1.3 in. (3.3 cm)

APERA Instruments DO 8500 Portable Optical Dissolved Oxygen Meter Kit Data Logger and Automatic Salinity

State-of-the-art Optical DO sensor measures dissolved oxygen RELIABLY and EFFORTLESS

Minimal maintenance required. Quick and easy calibration

Automatic compensation for salinity, temperature and air pressure

GLP/GMP data management, 500 groups of data storage, USB data output

The meter comes with a complete test kit including a 10 ft optical probe and salinity probe, a calibration cap and a sturdy carrying case

Probe head diameter for DO803 Luminescent Optical DO Probe: approximately 1.3 in. (3.3 cm)

Specifications

Dissolved Oxygen (DO) Measurement

Measuring Range:

0 to 20.00 mg/L (ppm)

0 to 200% oxygen saturation

Resolution:

0.01/0.1 mg/L (ppm)

0.1/1% (oxygen saturation)

Accuracy:

±2% of reading or ±2% oxygen saturation (take the higher value)

±2% of reading or ±0.2% mg/L (take the higher value) value)

Temperature Compensation Range: 0 to 100°C (32 to 212°F), automatic or manual

Calibration Points: Oxygen Saturation and Zero Oxygen

Temperature Measurement

Temperature Compensation: Automatic, 0 to 50°C (32 to 122°F)

Pressure Compensation: Automatic, 60 to 120 kPa

Salinity Compensation: Manual or Automatic

Temperature Range

Measurement Range: 0 to 50.0°C

Resolution: 0.1°C

Functions

Auto Hold: Yes

Date and Time: Yes

Data Storage: 500 sets

USB Output: Yes

Included Components

DO803 Optical DO Probe (3 meters)

2301T-F Conductivity/Temperature Electrode

Taksit seçenekleri için Üye Girişi Yapmalısınız.
Similar products
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
Proposal form
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.